Components
DSC03101-r-kl

Sensors in production

Litronic-FMS planar sensor P78-HR

The Liebherr P78-HR sensor in conjunction with the Liebherr Litronic-FMS 3K / CCS type coating thickness and basis weight determination system has become indispensable for many industrial processes.

The areas of use include the coating of paper, box, film, non-woven and textile webs.

The sensor installations take place, for example, before and after the squeegee for the exact determination of the coating or the humidity

The Litronic-FMS III evaluation and transfer unit, which is a mandatory part of the system, is used to record, process and prepare the values measured by the sensors.

The integrated software is used for convenient parametrisation and calibration. Thanks to the various interfaces, signal transmission to the higher-level control is feasible.

Measurement by the Liebherr sensor system is based on the physical principle of capacitance determination in the high-frequency stray field.

In addition to their high precision and robustness, the measuring devices from Bad Schussenried are characterised by their reproducibility.

Once the sensor has been calibrated, further measuring points can be set up or devices renewed on this basis at any time without great effort. The plant thus always remains reliable, regardless of its previous term and age.

Physical principleCapacity determination in the high frequency stray field
Frequency20 MHz
Measurement location1.) paper, cardboard, foil, fleece, textile webs
2.) Production, finishing and processing plants or comparable
Measuring range1) 0 - 100 % moisture content (measuring window adjustable) Basis weight determination 5... 25.000 ...50.000 g/m², solution 0.5 g/m²1.)
Coating thickness measurement 5 µm ... 25 mm ... 50 mm, solution 0.5 µm1
2) 0 - 100 % moisture content (measuring window adjustable)
Update cycle32.64 ms
Measurement value transferdigital: RS-485, streaming
Max. number of sensors on the bus16/4
Maximum bus length1200 m
Power supply8 - 30V, 0.4 VA
Material temperaturemax. 80 °C
Temperature measurement measuring range-10 – 80 °C
Measuring accuracy temperature measurement+/- 0.5 °C
Operating ambient temperature5 – 72 °C
Working temperature - electronics-20 – 80 °C
Storage temperature-25 – 80 °C
Wearing protectionAl2O3 (ZrO2) fine-grain stabilized aluminium oxide
Protection classIP68
Connection line length/typeLAPP UNITRONIC® ROBUST C 7x0.14 shielded/6 m
Housing/flange material1.4404
Dimensions: Ø/Height78 mm / 53 mm / 73 mm
Weight without cable0.960 kg
Clamping flange weight0.300 kg
1) (depending on material)

Characteristics

• Pure capacitive measuring method

• Non-contact measurement possible

• Temperature compensation

• Direct digital measurement value determination

• Digital measured value transmission

• Up to 4 sensors per evaluation module (FMS 3K) (Up to 16 sensors per evaluation module (FMS II))

• High quality stainless steel housing

Sales contact person

liebherr-pattern-contactperson

Liebherr-Mischtechnik GmbH

Im Elchgrund 12
88427 Bad Schussenried
Germany

Service contact person

liebherr-pattern-contactperson

Liebherr-Mischtechnik GmbH

Im Elchgrund 12
88427 Bad Schussenried
Germany