Augers for Kelly drilling
Results 11-20 of 26
No. of cutters - single-start
single-start
Pilot - Round shank chisel
Round shank chisel
Range of application - Very densely consolidated non-cohesive soils and low strength rock up to approx. 50 Mpa. and platy rock.
Very densely consolidated non-cohesive soils and low strength rock up to approx. 50 Mpa. and platy rock.
No. of cutters - single-start
single-start
Pilot - Round shank chisel
Round shank chisel
Range of application - Very densely consolidated non-cohesive soils and low strength rock up to approx. 50 Mpa. and platy rock.
Very densely consolidated non-cohesive soils and low strength rock up to approx. 50 Mpa. and platy rock.
No. of cutters - double-start
double-start
Pilot - Round shank chisel
Round shank chisel
Range of application - Very densely consolidated non-cohesive soils, low strength rock up to approx. 50 Mpa, platy rock and secant bored piled walls.
Very densely consolidated non-cohesive soils, low strength rock up to approx. 50 Mpa, platy rock and secant bored piled walls.
No. of cutters - double-start
double-start
Pilot - Round shank chisel
Round shank chisel
Range of application - Very densely consolidated non-cohesive soils, low strength rock up to approx. 50 Mpa, platy rock and secant bored piled walls.
Very densely consolidated non-cohesive soils, low strength rock up to approx. 50 Mpa, platy rock and secant bored piled walls.
No. of cutters - double-start
double-start
Pilot - Round shank chisel
Round shank chisel
Range of application - Very densely consolidated non-cohesive soils, low strength rock up to approx. 50 Mpa, platy rock and secant bored piled walls.
Very densely consolidated non-cohesive soils, low strength rock up to approx. 50 Mpa, platy rock and secant bored piled walls.
No. of cutters - double-start
double-start
Pilot - Round shank chisel
Round shank chisel
Range of application - Very densely consolidated non-cohesive soils, low strength rock up to approx. 50 Mpa, platy rock and secant bored piled walls.
Very densely consolidated non-cohesive soils, low strength rock up to approx. 50 Mpa, platy rock and secant bored piled walls.
No. of cutters - double-start
double-start
Pilot - none
none
Range of application - Medium-hard rock up to 60 MPa, fissured rock
Medium-hard rock up to 60 MPa, fissured rock
No. of cutters - double-start
double-start
Pilot - none
none
Range of application - Medium-hard rock up to 60 MPa, fissured rock
Medium-hard rock up to 60 MPa, fissured rock
No. of cutters - double-start
double-start
Pilot - none
none
Range of application - Medium-hard rock up to 60 MPa, fissured rock
Medium-hard rock up to 60 MPa, fissured rock
No. of cutters - double-start
double-start
Pilot - none
none
Range of application - Medium-hard rock up to 60 MPa, fissured rock
Medium-hard rock up to 60 MPa, fissured rock