Components

The modular rod sensor P45-GD for pipes and tanks is available in various rod lengths and can be used up to 75 bar. Retractable fittings are optional.

Water content determination Litronic-WMS II

Water cut meter / Analyzer

Liebherr sensors in use in explosive areas

The Liebherr Litronic-WMS II water content meter is used to measure the moisture or water content of a wide range of water content of a wide variety of media and materials in refineries, on oil platforms, in pipelines, in tanks, in many applications in the chemical and petrochemical industry, sludge dewatering, drying, waste incineration and sewage treatment plants. Also in the agricultural sector up to the pharmaceutical industry and many other industries.

The wide range of applications extends from the most diverse emulsions to the finest powders and dusts and coarse-grained materials (max. grain size 32 mm) such as

- Oil, crude oil, diesel, biodiesel, hardening oil (upstream / downstream)

- Coolants

- Paints, lacquers, solvents

- Wax, resin

- Other emulsions, suspensions

- Water-product separation

- Dust, slag

- Fertiliser

- Washing powder, agent

- Sawdust

- Biomass

- Flour

- etc.

Applications:

- Water cut meter

- Pipeline, tanks BS&W (Basic sediment and water) measurement

- Petroleum purification/desalination

- Automatic well testing

- LACT units

- Separation control

The stand-alone and precise measuring device for water content/moisture determination in the running process guarantees the highest quality and safety in EX-protected production environments, the further processing and refinement of very many emulsions and bulk materials.

The software enables fast and accurate calibration of the measured sections.

Liebherr offers sensors for the following device protection categories:

Certificates

ATEX / UKEX:

EU-type examination certificate number: EPS 21 ATEX 1 140 X / EPS 22 UKEX 1 159 X

DIN EN IEC 60079-0:2018, EN 60079-1:2014, EN 60079-11:2012, EN 60079-26:2015, EN 60079-31:2014

Gas EX-protection:

II 1/2 G Ex db/ia IIC T4 Ga/Gb

Dust EX-protection:

II 1/2 D Ex tb/ia IIIC T135°C Da/Db

IECEx:

Certificate number: IECEx EPS 21.0047X

IEC 60079-0:2017 Edition: 7.0, IEC 60079-1:2014-06 Edition: 7.0,

IEC 60079-11:2011 Edition: 6.0, IEC 60079-26:2014-10 Edition: 3.0,

IEC 60079-31:2013 Edition: 2

Gas EX-protection:

Ex db/ia IIC T4 Ga/Gb

Dust EX-protection:

Ex tb/ia IIIC T135°C Da/Db

The WMS II sensors are permitted for the following markets:

In addition to their high precision and robustness, the measuring devices from Bad Schussenried are characterised by their reproducibility.

Once the system has been calibrated, further measuring points can be set up or devices renewed on this basis at any time without great effort. The plant thus always remains reliable, regardless of its previous term and age.

Water Cut Meter Analyzer- Litronic-WMS II

Suitable for use in potentially explosive areasDust/Gas - Zone 0/20
Measurement
Physical principleCapacity determination in the high frequency stray field
Adjustable measuring range0 - 100 % moisture content (measuring window adjustable)
Update cycle65 ms
Temperature measurement accuracy± 0.5 °C
Outflow
Measured value transmission - Sensor display contentCurrent loop with “4 - 20 mA” for external display (option)
Measured value transmission - sensor PLC or main computerAnalogue: “4 - 20 mA” active at 500 Ohm digital: Hart Modem
Valid measurement3.75 mA to 21.6 mA (NAMUR)
Interface signal resolution16 bit
Max. length of connecting cable1000 m (depending on cable)
Power supply
ConnectionUn = 12 V DC (SELV/PELV)
Temperature
Medium temperature-5 °C* to 80 °C
Ambient temperature sensor head5 °C to 80 °C
Ambient temperature transmitter head 5 °C to 70 °C
Storage temperature-25 °C to 80 °C
* Under certain conditions
Pressure
Pressure-1 bar up to 75 bar
Material
Housing / rod material1.4571 (AISI 316TI)
Optional: 2.4819, Hastelloy®C-276, Alloy C-276
Transmitter head materialDie-cast aluminium, copper content of max. 0,1 %
Measuring field material/wearing protectionPEEK
Dimensions
Housing W/H/D88 mm
160 mm
143 mm
Rod diameter45 mm
Rod length6" to 32" (further lengths on request)
Measuring field materialPEEK
Measuring field positionFront or side

Sales contact person

Liebherr-Mischtechnik GmbH

Im Elchgrund 12
88427 Bad Schussenried
Germany

Service contact person

Liebherr-Mischtechnik GmbH

Im Elchgrund 12
88427 Bad Schussenried
Germany